CORECOOL 3.2.10 FEATURES:
- Foot Print Dimensions: 52″ length x 24″ wide x 36″ height
- 10 GPM units with programmable pressures up to 400 PSI
- Allen Bradley Compact Logix Programmable Control System with variable speed drive.
- Supply up to 20 Cooling Circuits (Number of circuits dependent on the inside diameter of cooling tube utilized. System capacity calculated utilizing 1.6 mm cooling tubes at 300 PSI)
- Cycle controlled and status monitored by discrete I/O or Network connection.
- 50 micron air filtration with mist separator.
- 50 micron water filtration.
- Water Filter monitoring system.
- Broken core detection system.
- Valve Failure detection system.
- Totalized flow monitoring system.
- Individual core flow monitoring (Purchased Option)
- 4 Timed Cooling Zones (Additional Zones Can be Purchased as an Option)
- UL and CSA certification (Supplied when requested)
CORECOOL Examples
Contact DPCS today to get your CORECOOL, a jet cooling technology, quote.
Page Tags: jet cooling, core cooling,corecool,die cast core cooling,porosity,high pressure core cooling,die cooling,core pins,jet cooled core pins,die high pressure cooling
Join Us on Social Media